Hitachi Healthcare Americas

ProSound F75 for Gynecology

prosound-f75

ProSound F75 Overview

The ProSound F75 supports various scan methods and a diversified lineup of speciality probes gives you a wide variety of imaging capabilities to meet all your imaging needs.

The new high-efficiency SmartProbes™ are very lightweight and designed to be high in energy conversion to transmit high-quality ultrasound beams without raising the temperature on the probe surface.

ProSound F75 Compound Pulse Wave Generator (CPWG) ProSound F75 Compound Pulse Wave Generator (CPWG) ProSound F75 Broadband Harmonics™ (BbH) Click image to enlarge ProSound F75 Full Aperture Apodization (FAA) Click image to enlarge ProSound F75  Adaptive Image Processing (AIP) ProSound F75  Adaptive Image Processing (AIP) Click image to enlarge ProSound F75 Spatial Compound Imaging (SCI) ProSound F75 Image Optimizer Image Optimizer OFF ProSound F75 Image Optimizer Image Optimizer ON ProSound F75 SmartProbes ProSound F75 SmartProbes

ProSound F75 Image Technology

Clear images and advanced functions are what you have come to expect from Hitachi – Aloka. Our 60 years of experience and innovation continues with the ProSound F75 platform.

  • Overview
  • Compound Pulse Wave Generator (CPWG) – The most advanced broadband beam-forming technology combined with high speed image processing that allows for higher definition ultrasound imaging than ever before.
  • Broadband Harmonics™ (BbH) – Provides high quality imaging using an expanded range of harmonic signals. This technology results in excellent image resolution and sensitivity and improved penetration.
  • Full Aperture Apodization (FAA) – Processes signals on all channels which significantly enhances focusing and sensitivity and allows for greater image uniformity.
  • Adaptive Image Processing (AIP) – Clearly displays differences in tissues, reducing speckle noise while maintaining the frame rate. It can also display outlines more clearly by selectively emphasizing boundaries.
  • Spatial Compound Imaging (SCI) – The ultrasound beam is transmitted and received in real time and in the multiple directions resulting in a reduction of speckle noise, suppression of artifacts, and improvement of contrast resolution allowing lesions to be clearly observed.
  • Image Optimizer – At the touch of a button the B-mode image is instantly optimized to the user’s preference. This technology continually monitors the user’s typical settings to optimally adjust the image when pressed resulting in less manual adjustments and more efficient examinations.
  • SmartProbes – The new high-efficiency probes are very lightweight and designed to be high in energy conversion to transmit high-quality ultrasound beams without raising the temperature on the probe surface.
ProSound F75 Ergonomics

ProSound F75 Ergonomics

3–directional simultaneous adjustment of the control panel

The operation panel of the ProSound F75 can be adjusted so that the switch layout matches the angle of the examiner's arm for comfortable examination. This panel moves sideways and back and forth, and can also be swiveled, fully adjusting to match the examiner's posture.

Flexible monitor arm

The angle, height, and distance of the monitor can be optimized for the examiner. The wide-view 19-inch high-resolution monitor is easy to view even from an acute angle.

Operation panel is less than 28 inches above the floor

The height of the operation panel a key point for comfortable examinations. That of the ProSound F75 can be lowered down to under 28 inches from the floor.

ProSound F75 Keyboard ProSound F75 Ease of Use

ProSound F75 Features

Real-Time 3D/4D

Real-time 3D allows the acquisition, optimization, manipulation and analysis of structures in 3D and Real-time 3D/4D

ProSound F75 Real-Time 3D/4D

Multi-Planar Reconstruction (MPR)

3D acquisition that provides images of multiple imaging planes including a third plane not accessible with conventional 2D imaging.

Multi-Planar Reconstruction (MPR)

eFLOW

Displays blood flow with directional information at higher frame rates and spatial resolution compared to conventional methods. Detail and accuracy of blood flow information is greatly increased with reduced blooming of color.

eFlow

Multi-Follicle Volume (MFV)

This 3D function decreases examination time as it automatically calculates the number and the volumes of regions of low brightness within a volume data. This function is particularly helpful in exams where multiple structures require volume measurement calculations such as patients undergoing the IVF process.

Multi-Follicle Volume (MFV)

Gynecologic Clinical Images

ProSound F75 - Uterus   MPR

Uterus MPR

ProSound F75 - Gyn MFV

Gyn MFV

ProSound F75 - Gyn FVM

Gyn FVM

ProSound F75 - Gyn   Ovarian Complex Lesion

Gyn Ovarian Complex Lesion

ProSound F75 - Gyn Ovarian Cysts

Gyn Ovarian Cysts

ProSound F75 - Uterus   SIP

Uterus SIP

ProSound F75 - 4D UterineAnamoly

4D UterineAnamoly

ProSound F75 - Uterus

Uterus

ProSound F75 - 3D Uterus MPR

3D Uterus MPR

Contact Info

Sales: 1-800-800-3106
Email: Sales_US@HitachiHealthcare.com